Step5: After connecting with the i-7540D_A, you can modify the

CAN parameters and network status of it. The CAN
parameters and network status of i-7540D_A and i-7540DB
are setting as following table.

i-7540D_A

i-7540D_B

CAN parameters

Specification: 2.0A

CAN baud rate: 1M bps

ACC: 00 00 00 00

ACM: FF FF FF FF

Err Response: No

Time-stamp Response: No

Specification: 2.0A

CAN baud rate: 1M bps

ACC: 00 00 00 00

ACM: FF FF FF FF

Err Response: No

Time-stamp Response: No

Network status

IP: 192.168.255.1

Mask: 255.255.0.0

Gateway: 192.168.0.1

IP: 192.168.255.2

Mask: 255.255.0.0

Gateway: 192.168.0.1

Note:

The network status changed after resetting the

system of these i-7540Ds.