5.1.6. Constellations

This catalog consists of 88 modern constellations with their names. They are listed alphabetically. A

list is attached in Appendix E.

5.1.7. Enter R.A. DEC

Here you can go to a target by entering its R.A. and DEC numbers.

5.2. Sync to Target

This operation will match the telescope's current coordinates to Target Right Ascension and

Declination. After slewing to an object, press MENU—then scroll to “Sync to Target” and press ENTER.
Follow the screen to do the sync. Using this function will re-calibrate the computer to the selected object.
Multiple syncs can be performed if needed. This operation is most useful to find a faint star or nebula near a
bright star.

Sync to Target” will only work after “Select and Slew” is performed. Otherwise, the system may

perform incorrectly. You can change the slewing speed to make the centering procedure easier. Simply
press a number (1 through 9) to change the speed. The default slew speed is 64X.

Sync to Target does the same thing as one star alignment except that you choose the object to

“sync” to. “One star align” chooses the star/object for you. “Sync to Target” operation will override any
previously performed “Two Star Align” operation.

5.3. Electric Focuser

For future iOptron electric focuser use.

5.4. Set Up Controller

5.4.1. Set Up Local Time

Refer to 4.3.1.

5.4.2. Set Up Observation Site

Refer to 4.3.2.

5.4.3. Set N/S Hemisphere

Refer to 4.3.3.

5.4.4. Set Display Contrast

Use arrow keys to adjust LCD display contrast.

5.4.5. Set Eyepiece Light

If you have an illuminated-reticule eyepiece or illuminated polar scope, and it is supported by

GoToNova hand controller, use this option to adjust the light intensity.

5.4.6. Set Backlight

Adjust LCD and keypad backlight.