SERVICING THE TOOL
Lubrication
Ingersoll--Rand No. 10
Ingersoll--Rand No. 68
Ingersoll--Rand No. 50
Always use an air line lubricator with these tools.
We recommend the following Filter--Regulator--Lubricator
Unit (FRL):
Inside USA use FRL unit #
C11--03--G00
Outside USA use FRL unit #
C26--C4--A29
After each two hours of operation, if an air line lubricator is
not used, inject 1/2 to 1 cc of Ingersoll--Rand No. 10 Oil into
the Air Inlet.
(Dwg. TPD905--2)
F
L
R
Main Line(s) Inner Ø
to be 3X Size of
Air Tool’s Inlet Ø
To Air
System
To Air
Tool
Lubricator
Emergency
Shut--Off
Valve
Regulator
Filter
Compressor
FRL
Drain Regularly
Branch Line(s) Inner Ø
to be 2X Size of
Air Tool’s Inlet Ø
SPECIFICATIONS
Model
Speed
Collet
H
Sound Level
dB(A)
z
Vibration Level
rpm
inches
mm
Pressure
Power
m/s
2
335SC4
35,000
1/4I
6
82.1
--------
3.7
330SC4
30,000
1/4I
6
82.8
--------
2.1
325SC4
25,000
1/4I
6
81.2
--------
1.8
325XC4
(3I Extension)
25,000
1/4I
6
82.2
--------
2.4
330XC4
(3I Extension)
30,000
1/4I
6
82.6
--------
1.9
H
Tested in accordance with PNEUROP PN8NTC1.2
z
Tested in accordance with ISO8662