beautypg.com

Ingersoll-Rand NO SE ENCUENTRA 150BMG User Manual

Page 4

background image

4

03524832_ed12

1. Disconnect the 1/4” hose at the “OUT” port on the Drive Housing,

and plug the hole in the Drive Housing with a 1/4” pipe plug.

2. Remove the 3/8” pipe plug from the center of the Motor Housing

Cover.

3. Engage the Drive Pinion with the flywheel by applying a

minimum of 70 psig (4.8 bar/483kPa) to the “IN” port on the Drive
Housing.

4. Insert a 5/16” hexagonal wrench through the hole in the Motor

Housing Cover to engage the hexagonal recess at the rear of the
Rotor.

5. Manually, rotate the Rotor until the engine is cranked to its

desired position.

Gas Operated Starters

WARNING

When repairing a gas-operated starter or when converting a
starter from air operation to gas operation, it is necessary to use
Ingersoll-Rand No. MBA31 Plastic Gasket, as directed, and the
following procedures for assembly and testing must be explicitly
followed.

1. Apply a thin film of sealant to the Housing Cover End Plug and

the Lubricator Port Plug as they are assembled.

2. Plug the exhaust. Connect air line to the inlet, regulate the air

pressure to 40 psig (2.8 bar/280 kPa) and immerse the unit for
30 seconds in light oil, or non-flammable solvent. If there are
any bubbles, the unit is unfit for gas operation. Tighten where
necessary and/or apply sealant to area showing leak. Retest.