8. SYMPTOM: THE WATER PULSATES OR
THERE IS MINIMUM WATER FLOW
a. This usually occurs only when the water level is
low. Add water to the level shown in step 3 on
page 8.
b. The filter may be dirty. Check the filter and
clean it if necessary.
9. SYMPTOM: THE WATER IS NOT BEING
CLEANED BY THE FILTER
a. Check to see if the filter is in place. Clean the
filter if it is dirty.
b. Check the chemical balance of the water. If the
pH is incorrect, the sanitizing agents will not
function properly.
10. SYMPTOM: THE WATER LEVEL DROPS
a. Some water loss due to evaporation is normal.
If rapid water loss occurs, or if you notice wet-
ness on the floor around the RENEW 207, the
spa shell may have a leak. Contact your local
spa and pool service provider for repairs.
b. A clamp or seal inside the pump compartment
may be loose. Check inside the pump compart-
ment for excess water, and watch the pump
unit while it is operating to see if water drips
from any of the plumbing. If you can identify the
location of the leak inside the spa jet unit, tight-
en the clamp or replace the damaged seal.
11. SYMPTOM: NO AIR FLOWS THROUGH THE
ADJUSTABLE HYDROTHERAPY JETS WHEN
THE AIR CONTROL IS TURNED COUNTER-
CLOCKWISE
a. The three adjustable thera-jets can be closed
and opened by pushing and pulling the noz-
zles. If no air flows through the thera-jets when
the air control is turned counterclockwise, sim-
ply pull the nozzles slightly.