IBM 8317 User Manual
Page 61

Diagnostic Error Code
FRU/Action
175-197-XXX
Thermal Sensor(s) test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
175-198-XXX
Thermal Sensor(s) test aborted
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Flash the system and re-test
3.
Go to
″Undetermined problems″ section
175-199-XXX
Thermal Sensor(s) test failed, cause
unknown
1.
Go to the
″Undetermined problems″
section
2.
Flash the system and re-test
3.
Replace component under function test
175-250-XXX
175-251-XXX
Thermal Sensor(s) limit error
1.
Check fans
2.
Check Power supply
3.
Microprocessor
4.
System board
185-000-XXX
Asset Security Test Passed
1.
No action
185-XXX-XXX
Asset Security failure
1.
Flash system
2.
System board
185-278-XXX
Asset Security Chassis Intrusion
1.
Assure Asset Security Enabled
2.
C2 Cover Switch
3.
System board
201-000-XXX
System Memory Test Passed
1.
No action
201-XXX-XXX
System Memory error
1.
Replace the memory module called out
by the test
2.
System board
202-000-XXX
System Cache Test Passed
1.
No action
202-XXX-XXX
System Cache error
1.
Cache, if removable
2.
System board
3.
Microprocessor
206-000-XXX
Diskette Drive Test Passed
1.
No action
206-XXX-XXX
Diskette Drive error
1.
Diskette Drive Cable
2.
Check power supply voltages
3.
Diskette drive
4.
System board
215-000-XXX
CD-ROM Drive Test Passed
1.
No action
Chapter 7. Symptom-to-FRU Index
55