Data Editing Command List
Enter Setup Mode
/E/D/FJ
Review Configuration
JY
Exit Data Editing
JZ
Delete Line
JS
Data Editing
JA
Enabled
1
Disabled
0
Unmatched Input
JB
Do Not Send
0
Send
1
Code IDs
JC
Enter JC
on page 29.
Set Length
JD
Enter JD
Match String
JE
Enter JE
position, and the string to match each character, followed by a
Count
JF
Type JF
the next end of field, each followed by a
Search String
JG
Enter JG
keyboard or function character chart, each character follo wed by a
Add Field
JJ
Enter JJ
new field from the keyboard or function character chart, each followed
by a
4 2
4 3
Send Field Sequence
JK
Enter JK
ters).
Add Delay
JM
Enter JM
the keyboard. Each unit equals 100 milliseconds. Examples
Examples
EXAMPLE ONE
76440057320712
Symbology
Code 128
Desired Output: Divide the input data record into two fields with one
consisting of the first six digits and the second containing the remain-
ing data. The output should have a
Formula
ID h C 06 A
Field List
Field A 764400
Field B 57320712
Field C
Keystroke Sequence
Enter Data Editing Setup
/E/D/FJ
Enter Data Editing and Enable
JA 1
Enter Track_ID and h (for Code 128)
JC h
Enter Count and 06
JF 0
Enter Add Field and
JJ ^N
Enter Field Sequence and ACBC JKA
ENTER>B
Enter Exit Setup
JZ
Output Data
764400
57320712