beautypg.com

Data editing command list, Examples – ID Tech 70 User Manual

Page 24

background image

Data Editing Command List

Enter Setup Mode

/E/D/FJ Clear JX

Review Configuration

JY

Exit Data Editing

JZ

Delete Line

JS

Data Editing

JA

Enabled

1

Disabled

0

Unmatched Input

JB

Do Not Send

0

Send

1

Code IDs

JC

Enter JC and the default Code ID(s) from Code ID Definition
on page 29.

Set Length

JD

Enter JDand two digits from the keyboard to indicate length.

Match String

JE

Enter JE, one digit one digit for the start
position, and the string to match each character, followed by a TER> (maximum 60 characters).

Count

JF

Type JF and enter two digits from the keyboard to indicate
the next end of field, each followed by a .

Search String

JG

Enter JG and enter characters for the search criteria from the
keyboard or function character chart, each character follo wed by a
.

Add Field

JJ

Enter JJ and sequentially the characters to be included in the
new field from the keyboard or function character chart, each followed
by a .

4 2

4 3

Send Field Sequence

JK

Enter JK and the field ID characters, each followed by
in the order to be sent (use upper case alphabetic charac-
ters).

Add Delay

JM

Enter JM and two digits, each followed by a from
the keyboard. Each unit equals 100 milliseconds. Examples

Examples

EXAMPLE ONE

76440057320712

Symbology

Code 128

Desired Output: Divide the input data record into two fields with one
consisting of the first six digits and the second containing the remain-
ing data. The output should have a inserted after each field.

Formula

ID h C 06 A SEND ACBC

Field List

Field A 764400
Field B 57320712
Field C

Keystroke Sequence
Enter Data Editing Setup

/E/D/FJ

Enter Data Editing and Enable

JA 1

Enter Track_ID and h (for Code 128)

JC h

Enter Count and 06

JF 0 6

Enter Add Field and character

JJ ^N

Enter Field Sequence and ACBC JKAC<

ENTER>BC

Enter Exit Setup

JZ

Output Data

764400
57320712

This manual is related to the following products: