Production chart, Specifications operating limits, Ari certified performance – Cornelius Series 50 User Manual
Page 4: Iacs-224 production chart, Dimensions/capacity, Iacs224, Iacs-227 production chart
![background image](/manuals/126973/4/background.png)
PRODUCTION CHART
AIR-COOLED
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
70
46 lbs.
41 lbs.
40 lbs.
80
44 lbs.
40 lbs.
40 lbs.
90
42 lbs.
38 lbs.
35 lbs.
Series 50†
Series 200
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant
Standard
Circuit
Maximum
Shipping Operating
Ambient
Water
Water
Voltage
Number Condenser
Type
Electrical
Capacity
Fuse Size
Weight
Weight
Temperature Temperature Pressure
Range
ACS50SL Air-Cooled
R-134a
115/60/1
15
15
110 lbs.
100 lbs.
50°F-100°F
45°F-90°F
20-120 psi 110-126
ARI CERTIFIED PERFORMANCE
Ice Harvest
Potable Water
KWH
Condenser
Capacity
Model
Rate
Use
Consumption
Water Use
Storage Bin
Number
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
per 100 lbs.
( lbs.)
IACS224
150
25.0
10.6
n/a
77
IWCS224
145
22.0
10.5
195
77
IACS227
240
27.0
9.8
n/a
75
IWCS227
240
27.0
7.6
160
75
IACS-224 PRODUCTION CHART
AIR-COOLED
WATER-COOLED
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
50
251 lbs.
226 lbs.
214 lbs.
50
221 lbs. 179 lbs.
171 lbs.
70
226 lbs.
198 lbs.
177 lbs.
70
218 lbs.
165 lbs.
155 lbs.
90
167 lbs.
150 lbs.
137 lbs.
90
164 lbs.
145 lbs.
130 lbs.
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant
Standard
Circuit
Maximum
Shipping Operating
Ambient
Water
Water
Voltage
Number
Condenser
Type
Electrical
Capacity
Fuse Size
Weight
Weight
Temperature Temperature Pressure
Range
IACS224
Air-Cooled
R-404a
115/60/1
15
15
182 lbs.
146 lbs.
50°F-100°F
45°F-90°F
20-120 psi 110-126
IWCS224 Water-Cooled
R-404a
115/60/1
15
15
182 lbs.
146 lbs.
50°F-100°F
45°F-90°F
20-120 psi 110-126
IACS227
Air-Cooled
R-404a
115/60/1
20
20
230 lbs.
198 lbs.
50°F-100°F
45°F-90°F
20-120 psi 110-126
IWCS227 Water-Cooled
R-404a
115/60/1
20
20
230 lbs.
198 lbs.
50°F-100°F
45°F-90°F
20-120 psi 110-126
ARI CERTIFIED PERFORMANCE
Ice Harvest
Potable Water
KWH
Condenser
Capacity
Model
Rate
Use
Consumption
Water Use
Storage Bin
Number
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
per 100 lbs.
(lbs.)
ACS50
38
38.5
14.3
n/a
25
DIMENSIONS/CAPACITY
Model
Nominal
Cabinet
Number
Capacity
Dimensions
Finish
ACS50
46 lbs.
15"w x 24"d x 34"h
E
DIMENSIONS/CAPACITY
Model
Nominal
Cabinet
Number
Capacity
Dimensions
Finish
IACS224/IWCS224
251 lbs
24"w x 24"d x 39"h
Polyethylene
IACS227/IWCS227
326 lbs
27"w x 28"d x 39"h
SS
†Limited lifetime warranty not applicable to this model.
ACS50
IACS227
Rated in accordance with ARI Standard 810 -91 and 820-88.
Rated in accordance with ARI Standard 810 -91 and 820-88.
24"
15"
34
"
28
"
27 "
39"
C
U
B
E
R
S
4
IACS224
24"
24"
39"
IACS-227 PRODUCTION CHART
AIR-COOLED
WATER-COOLED
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
50
326 lbs.
295 lbs.
271 lbs.
50
330 lbs. 300 lbs.
270 lbs.
70
312 lbs.
290 lbs.
267 lbs.
70
310 lbs.
280 lbs.
260 lbs.
90
263 lbs.
240 lbs.
220 lbs.
90
280 lbs.
240 lbs.
230 lbs.