Series 725, Series 500, Series 700 – Cornelius Series 50 User Manual
Page 12: Specifications operating limits, Af725pscr dimensions/capacity plumbing, Production chart, Dimensions/capacity plumbing

F
L
A
K
E
R
S
12
Series 725
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant
Standard
Circuit
Maximum
Shipping
Operating
Ambient
Water
Water
Voltage
Number
Condenser
Type
Electrical
Capacity
Fuse Size
Weight
Weight
Temperature
Temperature Pressure
Range
AF725PSCR Air-Cooled
R-404a
115/60/1
20
20
334 lbs.
300 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
AF725PSCR
DIMENSIONS/CAPACITY
PLUMBING
Model
Nominal
Cabinet
Water
Condensate
Number
Capacity
Dimensions
Finish
Bin Capacity
Inlets/Outlets
Drain
Bin Drain
AF725PSCR
654 lbs.
48"w x 30"d x 40"h
E or SS
300 lbs.
3
⁄
8
" male flare
1
⁄
2
" O.D. tube
3
⁄
4
" FPT
48 "
40 "
30
"
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
654 lbs.
588 lbs.
552 lbs.
70ºF
639 lbs.
563 lbs.
521 lbs.
90ºF
562 lbs.
479 lbs.
448 lbs.
Series 500
DIMENSIONS/CAPACITY
PLUMBING
Model
Nominal
Cabinet
Water
Electrical Service
Number
Capacity
Dimensions
Finish
Inlets/Outlets
Drainhose
Opening
WCF-510A
460 lbs.
14
1
⁄
2
"w x 25"d x 24
1
⁄
2
"h
SS
1
⁄
4
" male flare
3
⁄
8
" I.D. x
9
⁄
16
" O.D.
7
⁄
8
" diameter hole
WCF-510W
460 lbs.
14
1
⁄
2
"w x 25"d x 24
1
⁄
2
"h
SS
1
⁄
4
" MF /
3
⁄
8
" FPT
3
⁄
8
" I.D. x
9
⁄
16
" O.D.
7
⁄
8
" diameter hole
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Water
Voltage
Number
Condenser
Type
Electrical Capacity
Fuse Size
Weight
Weight
Temperature Temperature Pressure
Range
WCF-510A
Air-Cooled
R-404a
115/60/1
15
15
154 lbs.
142 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
WCF-510W
Water-Cooled
R-404a
115/60/1
15
15
154 lbs.
142 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
460 lbs.
412 lbs.
388 lbs.
70ºF
442 lbs.
394 lbs.
371 lbs.
90ºF
407 lbs.
367 lbs.
349 lbs.
Series 700
DIMENSIONS/CAPACITY
PLUMBING
Model
Nominal
Cabinet
Water
Electrical Service
Number
Capacity
Dimensions
Finish
Inlets/Outlets
Drainhose
Opening
WCF-710A
936 lbs.
14
1
⁄
2
"w x 25"d x 24
1
⁄
2
"h
SS
1
⁄
4
" male flare
3
⁄
8
" I.D. x
9
⁄
16
" O.D.
7
⁄
8
" diameter hole
WCF-710W
936 lbs.
14
1
⁄
2
"w x 25"d x 24
1
⁄
2
"h
SS
1
⁄
4
" MF /
3
⁄
8
" FPT
3
⁄
8
" I.D. x
9
⁄
16
" O.D.
7
⁄
8
" diameter hole
WCF-710R
936 lbs.
14
1
⁄
2
"w x 25"d x 24
1
⁄
2
"h
SS
1
⁄
4
" male flare
3
⁄
8
" I.D. x
9
⁄
16
" O.D.
7
⁄
8
" diameter hole
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant
Standard
Circuit Maximum Shipping Operating
Ambient
Water
Water
Voltage
Number
Condenser
Type
Electrical
Capacity Fuse Size
Weight
Weight
Temperature Temperature Pressure
Range
WCF-710A
Air-Cooled
R-404a
115/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
WCF-710W
Water-Cooled
R-404a
115/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
WCF-710R*
AC Remote
R-404a
115/60/1
20
20
138 lbs.
126 lbs.
50°F-100°F
50°F-90°F
20-120 psi 110-126
WCF-710A
Air-Cooled
R-404a
208-230/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
WCF-710W
Water-Cooled
R-404a
208-230/60/1
20
20
163 lbs.
152 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-253
*Use Remote Condenser WCU.
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
936 lbs.
838 lbs.
789 lbs.
70ºF
892 lbs.
796 lbs.
750 lbs.
90ºF
779 lbs.
701 lbs.
667 lbs.
WCF710/B842SS
32"
42"
14
1
⁄
2
"
72
1
⁄
2
"
24
1
⁄
2
"
32
5
⁄
1
6
"
WCF510/B530SS
30"
14
1
⁄
2
"
72
1
⁄
2
"
24
1
⁄
2
"