I.R.I.S. P406TAT User Manual
Page 2

IRiS • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
02/28/2008 9:02:28 AM
Specifications and Dimensions subject to change without notice.
ADI070195
.
P406TAT MV4CMH20MR E4PINSR
D
FC
CB
8'
39
3.6'
9'
31
4.0'
10'
25
4.4'
12.5'
16
5.6'
15'
11
6.7'
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
1
1
1
1
1
21
110
864
2302
2488
Zone
Lumens
%
Lamp
%
Luminaire
0- 30
510
51
96.4
0- 40
524
52.4
99
0- 60
526
52.6
99.4
0- 90
529
52.9
100
90-180
0
0
0
0-180 529
52.9
100
Spacing Criterion = .4
Efficiency = 52.9%
Test No. P11075
Platform = P4
Element = E4PINSR
Lumens = 1000
Lamp = CDM20/MR16/
FL25
20W
CMH MR16
Downlight
45°
30°
15°
0°
60°
75°
90°
850
1700
2550
Ceiling
Wall %
RCR
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
Zonal cavity method -- floor reflectance = 20%
0
63 63 63 63
62 62 62 62
59 59 59
56 56 56
54 54 54
53
1
61 60 59 58
60 59 58 57
57 56 55
55 54 54
53 52 52
51
2
59 57 56 54
58 56 55 54
55 54 53
53 52 51
52 51 50
50
3
57 55 53 52
56 54 53 51
53 52 50
52 51 50
51 50 49
48
4
56 53 51 49
55 52 51 49
51 50 49
50 49 48
49 48 48
47
5
54 51 49 48
53 51 49 47
50 48 47
49 48 47
48 47 46
46
6
53 50 47 46
52 49 47 46
49 47 46
48 46 45
47 46 45
44
7
51 48 46 45
51 48 46 44
47 46 44
47 45 44
46 45 44
43
8
50 47 45 43
50 47 45 43
46 44 43
46 44 43
45 44 43
42
9
49 46 44 42
48 45 43 42
45 43 42
45 43 42
44 43 42
41
10
48 44 42 41
47 44 42 41
44 42 41
44 42 41
43 42 41
40
Photometric Results
Candlepower Distribution
Coefficients of Utilization
Cone of Light
Zonal Lumens Summary
Candelas
D
FC
CB
8'
96
2.2'
9'
76
2.5'
10'
62
2.8'
13'
36
3.6'
16'
24
4.4'
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
1
1
1
1
1
22
61
630
4678
6168
Zone
Lumens
%
Lamp
%
Luminaire
0-30
573
57.3
97
0-40
587
58.7
99.2
0-60
589
58.9
99.5
0-90
591
59.1
100
90-180
0
0
0
0-180 591
59.1
100
Spacing Criterion = .3
Efficiency = 59.1%
Test No. P10975
Platform = P4
Element = E4PINSR
Lumens = 1000
Lamp = CMH20/MR16/
G10/SP 12°
20W
CMH MR16
Downlight
45°
30°
15°
0°
60°
75°
90°
2100
4200
6300
Ceiling
Wall %
RCR
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
Zonal cavity method -- floor reflectance = 20%
0
70 70 70 70
69 69 69 69
66 66 66
63 63 63
60 60 60
59
1
68 67 66 65
67 66 65 64
64 63 62
61 61 60
59 59 59
58
2
66 65 63 62
65 64 62 61
62 61 60
60 59 59
59 58 57
57
3
65 63 61 59
64 62 60 59
60 59 58
59 58 57
58 57 56
56
4
63 61 59 57
63 60 58 57
59 58 56
58 57 56
57 56 55
55
5
62 59 57 56
61 59 57 55
58 56 55
57 56 55
56 55 54
54
6
61 58 56 54
60 57 56 54
57 55 54
56 55 54
55 54 53
53
7
60 57 55 53
59 56 54 53
56 54 53
55 54 53
55 53 52
52
8
59 55 53 52
58 55 53 52
55 53 52
54 53 52
54 52 52
51
9
58 54 53 51
57 54 52 51
54 52 51
53 52 51
53 52 51
50
10
57 53 52 50
56 53 52 50
53 51 50
53 51 50
52 51 50
50
Photometric Results
Candlepower Distribution
Coefficients of Utilization
Cone of Light
Zonal Lumens Summary
Candelas