beautypg.com

IMC Networks IE–ModeConverter User Manual

Page 8

background image

5

DC Power Supply Precautions

The following precautions must be observed when installing the chassis model with
an internal DC power supply.

1. Check nameplate ratings to ensure there is no overloading of supply circuits that

could effect overcurrent protection and supply wiring.

2. In addition, the following must be observed:

a. Connect the equipment to a 35 to 50 VDC power source that is electrically

isolated from the alternating current source. The 35 to 50 VDC power
source is connected to a SELV DC source.


b. Route input wiring to terminal block and secure in such a manner that it is

protected from damage and stress. Do not route wiring past sharp edges or
moving parts.


c. Incorporate a readily accessible disconnect device, with a 3mm minimum

contact gap in the fixed wiring.

3. Reliable Earthing of this equipment must be maintained. Particular attention

should be given to supply connections when connecting to power strips, rather
than direct connections to the branch circuit.

IMC Networks Technical Support

Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada);

+32-16-550880

(Europe)

Fax: (949) 465-3020

E-Mail: [email protected]

Web:

www.imcnetworks.com