To Remove the Condenser Fan Motor Assembly:
1. Disconnect electrical power to the ice machine
2. Remove top panel and the service panels.
3. Unplug the fan motor wire leadsfrom the fan motors.
4. Remove the two (2)head bolt from the top end of the fan motor assembly. (Fig 1)
5. Lift up the fan motors and bracket assembly about ½ inch and pull out the fan

assembly out the right service access hole. (Fig 2)

6. Repair as needed.
7. To Reassemble: Place the fan motor assembly lower flange holes over the two Allen

head cap screws in the base, and install the hex head bolts at the top of the assembly.
Plug the fan motors back in and replace the panels.