The Ikelite Digital Housing should be given the same care and

attention as your other photographic equipment In addition to

normal maintenance we recommend that the housing be returned

to Ikelite periodically to be checked and pressure tested

D

Doo N

Noott leave the camera and housing in direct sunlight for

prolonged periods Heat may damage the camera

D

Doo N

Noott ship the camera in the housing

Before using the housing always check the tightness of the sseett

ssccrreew

w in each control knob

Check each ccoonnttrrooll ggllaanndd penetrating the housing to make sure

they are tight There is a slight chance that either could vibrate

loose during travel

Keep the back o’ring clean and lightly lubricated To lubricate

remove the o’ring from the back Put a small amount of lkelite

lubricant on your fingers Draw the o’ring through your fingers

to apply a light coating of lubricant Only apply enough

lubricant to make the o’ring feel slick D

Doo N

Noott ssttrreettcchh tthhee oo’’rriinngg

This light coating of lubricant will help to keep the o’ring from

drying out and will help to show a dark sealing line when the

housing back is properly sealed

Keep the area where the o’ring fits and the sealing surface of

the housing clean

Rinse the housing exterior thoroughly in fresh water after each

salt water use Dry with a soft cloth Dry lens port to eliminate

water spotting

After several uses in salt water soak the housing exterior in a

mild soap solution rinse and dry before storage When storing

the housing remove the back o’ring lightly lubricate and place

in a plastic bag Place the plastic bag with o’ring inside the

housing for safe keeping

CCAAU

UTTIIO

ON

N

N

Neevveerr uussee sspprraayy lluubbrriiccaannttss aass tthhee pprrooppeellllaanntt iinnggrreeddiieenntt ccaann

ccaauussee tthhee ppllaassttiicc hhoouussiinngg ttoo ccrraacckk

15

CCoonnttrrooll M

Maaiinntteennaannccee

Ikelite controls are designed to provide years of reliable service

with minimal maintenance

Push button controls require no maintenance other than rinsing

in fresh water after saltwater use If a push button control

becomes difficult to push or if it sticks when depressed soak the

housing in luke warm fresh water After a few minutes operate

the push button If this does not correct the problem return the

housing to Ikelite for maintenance

Some of the controls have long shafts These controls can be

pulled out exposing the shaft (see drawing)

To lubricate the control gently pull on the knob until the

stainless steel shaft is exposed Lightly lubricate the shaft then

move the shaft in and out several times This will lubricate the

x’ring in the Ikelite control gland This should be done before

using the housing after a prolonged storage period or once a

week when the housing is in use

housing

lubricate shaft

pull out to
expose shaft

16

CCoonnttrrooll M

Maaiinntteennaannccee CCoonntt

Some of the controls have a short shaft and cannot be pulled

out exposing the shaft for lubrication In the unlikely event one

of these controls sticks or becomes difficult to operate you can

remove the control from the housing and lubricate it or return

the housing to Ikelite for maintenance To remove the control

loosen the set screw in the knob (allen wrench required);

remove the knob If there is salt or dirt build up on the exposed

control shaft clean the shaft Open the housing and gently slide

the control shaft out of the control gland Clean and lightly

lubricate the shaft including the end of the shaft Slide the

shaft back into the control gland and gently slide it back and

forth a few times without fully removing the shaft from the

gland Replace the knob NOTE the flat area on the shaft the

set screw in the knob should tighten down against the flat area

on the control so the knob does not turn on the shaft

Loosen set screw
(allen wrench required)

Flat

Tighten set screw down

against this area when

replacing the knob.

housing

gland

control
shaft

Lubricate end of shaft
before reinserting into
gland