Action, Snmp oid, Options – Intermec 700 User Manual
Page 337

Configurable Settings
Appendix
—
A
313
700 Series Color Mobile Computer User’s Manual
MSI
MSI is a symbology similar to Plessey code (page 312) that includes a start
pattern, data characters, one or two check digits, and a stop pattern. Note
that this is not available when you use an imager with your 700 Color Com-
puter.
Action
Tap (+) to expand the MSI parameter, select the setting to be changed,
then select an option to change this setting or select an option from the
drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.15.1
Options
Decoding
0
1
Not active (default)
Active
Check digit
0
1
2
3
Mod 10 transmitted (default)
Mod 10 not transmitted
Double Mod 10 transmitted
Double Mod 10 not transmitted
Bar code length
0
1
Any length
Minimum length (default)
Minimum length
001–254
Minimum length 1–254 (default is 6)
Note: If Bar code length = “1” then Minimum length is entered.