beautypg.com

Echnical specification – IDEAL INDUSTRIES Dual View Thermal Imaging Camera HeatSeeker 160 User Manual

Page 23

background image

#61-846

ND-7521-1

Page 23 of 25

A3. Technical specification

Performance
Field of View:

20° X 15°

Focus:

Manual

Minimum Focus:

30cm

Spectral response:

8µm to 14µm

Thermal Sensitivity:

NETD 80mK (0.08°C) @ 23°C ambient and

30°C scene temperature.

Detector:

160×120 Pixels uncooled microbolometer

Measurement

Temperature range: 14 F to +482 F (-10 C to +250 C)

Radiometry:

Four moveable temperature measurement cursors giving automatic

temperature difference measurement and auto locking onto hottest and
coldest points

Emissivity Correction: User selectable 0.1 to 1.0 in steps of 0.01 with reflected ambient

temperature compensation. The four measurement cursors can have
individual emissivity values assigned to them.

Accuracy:

The greater of ±2 C or ±2% of reading in C for the operating
temperature range of -15 C to +45 C.

Display
3 ½” colour LCD with LED backlight with 8 color palettes
Thermal images or visible images or mixed thermal and visible images including picture in
picture.
Electronic zoom (IR and visible): x2; x4; Image integration: Up to x4
Image Storage
Over 1000 images on supplied micro-SD card
Laser Pointer
A built in Class 2 laser is supplied to highlight the center of the thermal image. (Aligned at 6
feet)
Beam Divergence: <0.2mrad

Maximum Output:

<1mW

Imager power Supply
Battery:

Rechargeable Lithium-Ion field replaceable battery with up to 5 hours
continuous operation; charge through the USB port

AC Operation:

USB AC power adaptor supplied

Mechanical
Housing:

Impact resistant plastic with over molded soft plastic.

Dimensions:

130mm X 95mm X 220mm

Weight:

0.8Kg

Mounting:

Handheld & tripod mounting

1

/

4

" BSW.

Settings and Controls

Auto/user selectable span and level control.
• Readout in °C or °F
• Four moveable temperature measurement cursors with individual emissivity values and

temperature difference between two points.

• User selectable emissivity setting for each measurement cursor.
• Auto hot and cold seeking or hot only or cold only.
• User selectable reflected temperature compensation.
• Area analysis – 3 options.
• X-Y thermal profiles.