Nfrared settings – IDEAL INDUSTRIES Dual View Thermal Imaging Camera HeatSeeker 160 User Manual
Page 12
#61-846
ND-7521-1
Page 12 of 25
5.1.
Infrared settings
Emissivity
Set the emissivity value between 0.10 and 1.00 using the left/right navigation
buttons.
Pressing Function Key 3 ( Table) gives a table of emissivity values of common
materials from which a selection can be made.
Note that if more than one cursor is selected, individual emissivity’s can
be assigned to each cursor.
Palette
Display the image using different colour palettes.
1. Ironbow
5.
High Contrast
2. Rainbow
6.
Rainbow 16
3. Isotherm Style
7.
Black Hot
4. Hot Metal
8.
White Hot
Reflected Temp
Set this to the ambient temperature to correct for reflected radiation when an
emissivity of less than 1 is selected.
Temp units
Choose between C and F.
Integration
Chose an integration period from 1 (fast) to 4 (slow).
A longer integration time will reduce the noise in the image, but will slow down the
response to moving images.
Interpolation
Choose Off or On.
This shows or hides the thermal image pixelation.