beautypg.com

Section 6 − maintenance & troubleshooting, 1. routine maintenance, 2. changing gun contact tip – Miller Electric 15A User Manual

Page 20: 3 months, 6 months

background image

OM-1213 Page 16

SECTION 6 − MAINTENANCE & TROUBLESHOOTING

6-1. Routine Maintenance

Y Disconnect power

before maintaining.

.

Maintain more often
during severe conditions.

3 Months

Replace

Damaged Or

Unreadable

Labels

Replace

Damage

Gas Hose

Clean

And

Tighten

Weld

Terminals

Repair Or Replace

Cracked Cables

And Cords

6 Months

Blow Out Or

Vacuum Inside

Clean

Drive

Rolls

6-2. Changing Gun Contact Tip

Ref. 150 437-A

2

1

Remove nozzle
1

Nozzle

2

FasTip

Unscrew FasTip.
Install new FasTip.