8-11. Voltmeter/Ammeter Help Displays

Use the Voltmeter/Ammeter help

displays to diagnose and correct

fault conditions.

.

When a help code is displayed
normally weld output has

stopped but generator power

output may be okay.

.

To reset help displays, stop

unit and then restart. See item

6 below to reset Help 25 dis-

play.

1

Help 20 Display

Indicates a failure of meter display

module PC2, or the wiring between

PC2 and main control module PC1.

If this display is shown, have Facto-

ry Authorized Service Agent check

PC1, PC2, and the wiring between

PC1 and PC2.
2

Help 21 Display

Indicates thermistor TH1 on the

main rectifier heat sink has failed.

If this display is shown, have Facto-

ry Authorized Service Agent check

TH1, and the wiring between TH1

and PC1.
3

Help 22 Display

Indicates the rectifier heat sink has

overheated. If this display is shown,

check generator cooling system

and/or reduce duty cycle. Keep en-

gine access door closed when run-

ning to maintain proper cooling air

flow past rectifier. Allow unit to cool

before restarting. If problem contin-

ues, have Factory Authorized Ser-

vice Agent check unit.
4

Help 23 Display

Indicates one of the rectifier output

SCR’s has failed. If this display is

shown, have Factory Authorized

Service Agent check the rectifier

SCR’s.
5

Help 24 Display

Indicates weld open circuit voltage

(OCV) is too high (above 41 volts

dc). If this display is shown, have

Factory Authorized Service Agent

check main control module PC1.
6

Help 25 Display

Indicates a remote device con-

nected to Remote Receptacle

RC14 may be faulty. Help 25 is also

displayed whenever a remote de-

vice has been connected to RC14

and then disconnected. Clear fault

by stopping and restarting the unit

or by turning Process/Contactor

switch to another position. If prob-

lem continues, have Factory Autho-

rized Service Agent check the re-

mote device, filter board PC6, and

main control module PC1.

2

1

HL.P

22

HL.P

23

HL.P

24

HL.P

25

HL.P

20

HL.P

21

6

5

4

3

803 562 / 217 357-A