9. connecting to remote 14 receptacle rc14, Work like a pro – Miller Electric Big Blue 300 P User Manual
Page 27
OM-4433 Page 23
5-9. Connecting To Remote 14 Receptacle RC14
Socket*
Socket Information
24 VOLTS AC
A
24 volts ac. Protected by sup-
plementary protector CB8.
24 VOLTS AC
B
Contact closure to A completes
24 volt ac contactor control
circuit.
C
Output to remote control:+10
volts dc in MIG mode; 0 to +10
volts dc in Stick or TIG mode.
REMOTE
OUTPUT
D
Remote control circuit common.
LDR-14 long
distance remote
(includes 120 V
receptacle)
OUTPUT
CONTROL
E
DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
p
)
115 VOLTS AC
I
115 volts, 10 amperes, 60 Hz
ac. Protected by supplementary
protector CB7.
OR
J
Contact closure to I completes
115 volt ac contactor control
circuit.
OR
F
Current feedback: 1 volt per
100 amperes.
H
Voltage feedback: 1 volt per 10
arc volts.
803 562
GND
K
Chassis common.
NEUTRAL
G
Circuit common for 24 and 115
volt ac circuit.
*The remaining sockets are not used.
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.