ST4125G/ST6125G SUBMERSIBLE PUMP — SPECIFICATIONS
Table 1. Specifi cations
Model
ST4125G
ST6125G
Type
Centrifugal Submersible Pump
Centrifugal Submersible Pump
Impeller
Cast Ductile Iron
Cast Ductile Iron
Discharge Size
4.00 in. (101 mm)
6.00 in. (152 mm)
Max Solids
.078 in (2 mm)
.078 in (2 mm)
Maximum Pumping Capacity
380 gallons/minute
(1,438 liters/minute)
TBD
Max Head
111 ft. (33.8 meters)
TBD
Power
10 HP (7.5 kw)
15 HP (11 kw)
Voltage/Phase
230/460 3Ш
230/460 3Ш
Starting Amps
180 (230V)
90 (460V)
TBD
Running Amps
24 (230V)
12 (460V)
TBD
Max Starts/Hr.
30
30
Enclosure Type
68
68
Insulation Class
F
F
Max Temperature
104° F (40° C)
104° F (40° C)
Control Box Required
See Note 3
See Note 3
Power Cable Length
50 ft. (15.2 m)
50 ft. (15.2 m)
Dry Weight
344 lb (156 kg)
TBD)
Max Height
33.5 in (85.09 cm)
TBD
Max Diameter
14.0 in (35.56 cm)
TBD
1. Motor Rotation – Let pump hang freely from a lifting device. Start and stop pump while observing movement
(kick) of pump. If connected correctly the impeller will rotate clockwise (CW) as viewed from above. If pump rotates
counterclockwise interchange any two phases from the power source.
2. Mechanical Seal Oil – Use ISO VG32 lubrication oil, Mobile DTE 24 turbine oil 90 or equivalent. Fill oil chamber 75%
to 85% full (allow air space for expansion).
3. Control Box - For unattended operation, CB12 or CB14 Control Box (Table 3) is required. Control boxes will provide
thermal overload protection.