Scanner and cable terminations, Scanner pinout connections – Metrologic Instruments IS3480-00 User Manual
Page 43
39
S
CANNER
AND
C
ABLE
T
ERMINATIONS
Scanner Pinout Connections
IS3480-102 RS232, TTL
Pin
Function
1
Ground
2
Transmit (Full RS232)
3
Receive (Full RS232)
4
RTS Output (TTL RS232)
5
CTS Input (TTL RS232)
6
DTR Input (TTL RS232)
7
Transmit (TTL RS232)
8
Receive (TTL RS232)
9
+5VDC
The IS3480 scanner interfaces terminate
to a 10-pin modular socket. The serial #
label indicates the interface enabled when
the scanner is shipped from the factory.
Figure 15.
10
Shield Ground
IS3480-47 Keyboard Wedge
and Stand-Alone Keyboard
IS3480-41
RS232C and Light Pen Emulation
Pin
Function
Pin
Function
1
Ground
1
Ground
2
RS232 Transmit Output
2
RS232 Transmit Output
3
RS232 Receive Input
3
RS232 Receive Input
4
PC Data
4
RTS Output
5
PC Clock
5
CTS Input
6
KB Clock
6
DTR Input/LTPN Source
7
PC +5V
7
Reserved
8
KB Data
8
LTPN Data
9
+5VDC
9
+5VDC
10
Shield Ground
10
Shield Ground
IS3480-40 Full Speed USB
RS232 Low Speed USB,
HID IS3480-38 and POS IS3480-39
Pin
Function
Pin
Function
1
Ground
1
Ground
2
RS232 Transmit Output
2
No Connect
3
RS232 Receive Input
3
No Connect
4
RTS
4
No Connect
5
CTS
5
No Connect
6
USB D+
6
D+
7
V USB
7
PC +5V/V_USB
8
USB D-
8
D-
9
+5VDC
9
No Connect
10
Shield Ground
10
Drain Wire
Continued on next page.