Electrical, Environmental – Metrologic Instruments IS3480-00 User Manual
Page 35
31
D
ESIGN
S
PECIFICATIONS
IS3480
Electrical
Voltage Supply:
5VDC ± 0.25V
Operating Power:
1.375 W
Standby Power:
1.0 W
Operating Current:
275 mA typical at 5VDC
Standby Current:
200 mA typical at 5VDC
DC Transformers:
Class II; 5.2VDC @ 650 mA
Laser Class 1:
IEC 60825-1:1993+A1:1997+A2:2001
EN 60825-1:1994+A11:1996+A2:2001
EMC:
FCC, ICES-003 & EN 55022 Class A
Environmental
Operating Temperature:
-20°C to 40°C (-4°F to 104°F)
Storage Temperature:
-40°C to 60°C (-40°F to 140°F)
Humidity:
5% to 95% relative humidity, non-condensing
Contaminants:
Sealed to resist airborne particulate contaminants
Ventilation:
None required
Specifications subject to change without notice.
See also other documents in the category Metrologic Instruments Scanners:
- VoyagerCG MS9500 (2 pages)
- MS2122 (2 pages)
- IS4910 Series (42 pages)
- MS7600 (2 pages)
- StratosH MS2300 Series (1 page)
- IS4815 (48 pages)
- MS6130 MX003 (44 pages)
- MLPN 2168 (20 pages)
- StratosS MS2221 (68 pages)
- ARGUSSCANTM MS7220 (52 pages)
- MS2421 (66 pages)
- FocusBT MS1633 (52 pages)
- Stratos MS2xxx Series (88 pages)
- MS9535 (56 pages)
- 1070 (21 pages)
- MS7100 (45 pages)
- MLPN 2159 (28 pages)
- MS9524 (56 pages)
- MS700i (60 pages)
- MS9500 (2 pages)
- 185 (1 page)
- StratosS MS2220 (86 pages)
- MX003 (45 pages)
- StratosS MS2200 Series (2 pages)
- MS9500 Voyager (56 pages)
- TECH 7 (32 pages)
- MS6520 (48 pages)
- SP5500 (2 pages)
- IS1650 (2 pages)
- IS8000 Series (40 pages)
- MS7120 Series (48 pages)
- IS4921 (61 pages)
- Laser Scanner (56 pages)
- MS 5145 (2 pages)
- MS860 (55 pages)
- MS3580 (56 pages)
- MS3580 (2 pages)
- MS1890 (48 pages)
- MS6720 (52 pages)
- Cubit IS6520 Series (44 pages)
- IS8000 (40 pages)
- MS1890 Focus (2 pages)
- MS1690 (52 pages)
- Hand-Held Scanner (13 pages)