beautypg.com

Manual reset burner hi-limit instructions – Maytag MDG50PCC User Manual

Page 32

background image

28

Maytag Co.

113198 - 5

SECTION IX

MANUAL RESET BURNER HI-LIMIT INSTRUCTIONS

This dryer was manufactured with a manual reset burner hi-limit thermostat, which is monitored by the Phase 7
computer. If the burner hi-limit is open prior to the start of the drying cycle, the dryer will start momentarily and
then shut down, the Phase 7 computer will display “BURNER HIGH LIMIT FAULT” with an audio indication.

If the burner hi-limit opens during a drying cycle, the Phase 7 computer will also display the same error code
described above, along with an audio indication. If the drum temperature is above 100° F (38° C), the dryer will
continue to run with no heat for 3 minutes or until the drum temperature has dropped below 100° F (38° C). The
pause key must be held down for 3-seconds to clear the fault. The open burner hi-limit must be reset “manually”
prior to the start of the next cycle.

WARNING: Discontinue power to dryer before attempting to reset hi-limit.