6. control box connections, 7. 14-pin plug information – Miller Electric SS-74S12 User Manual
Page 16

OM-1500−11 Page 12
Ref. 803 019
1
Interconnecting Cable
Receptacle
2
Interconnecting Cable
3
14-Pin Control Cable
4-6. Control Box Connections
1
2
3
4-7. 14-Pin Plug Information
Pin*
Pin Information
A
24 volts ac with respect to socket G.
B
Contact closure to A completes 24 volts ac contactor control circuit.
A
J
K
G
Circuit common for 24 volts ac circuit.
A
J
B
K
I
L
N
H
C
+10 volts dc output to remote control with respect to socket D.
C
L
N
H
D
M
G
D
Remote control circuit common.
D
M
G
E
F
E
0 to +10 volts dc input command signal from remote control with respect to socket D.
H
Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.
F
Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.
*The remaining pins are not used.