Scanner and cable terminations, Scanner pinout connections – Metrologic Instruments IS3480 User Manual
Page 42
www.metrologic.com
38
S
CANNER
AND
C
ABLE
T
ERMINATIONS
Scanner Pinout Connections
The IS3480 scanner interfaces terminate to a 10-pin modular socket.
The serial number label indicates the interface enabled when the scanner is
shipped from the factory.
Figure 14.
IS3480-47 Keyboard Wedge
and Stand-Alone Keyboard
IS3480-41
RS232 and Light Pen Emulation
Pin Function
Pin Function
1 Ground
1 Ground
2
RS232 Transmit Output
2
RS232 Transmit Output
3
RS232 Receive Input
3
RS232 Receive Input
4 PC
Data
4 RTS
Output
5 PC
Clock
5 CTS
Input
6
KB Clock
6
DTR Input/LTPN Source
7 PC
+5V
7 Reserved
8 KB
Data
8 LTPN
Data
9 +5VDC
9 +5VDC
10 Shield
Ground
10 Shield
Ground
IS3480-38
RS232 Low Speed USB
IS3480-11
RS485
Pin Function
Pin Function
1 Ground
1 Ground
2
RS232 Transmit Output
2
RS232 Transmit Output
3
RS232 Receive Input
3
RS232 Receive Input
4 RTS
Output
4 RTS
Output
5 CTS
Input
5 CTS
Input
6 D+
6 DTR
Input
7 V_USB
7 IBM
B-Transmit
8 D-
8 IBM
A+
Receive
9 +5VDC
9 +5VDC
10 Shield
Ground
10 Shield
Ground
Applicable for IBM
®
Host applications.
Continued on next page.