Scanner and cable terminations, Scanner pinout connections – Metrologic Instruments MS7120 User Manual
Page 40

36
1
10
S
CANNER AND
C
ABLE
T
ERMINATIONS
Scanner Pinout Connections
The MS7120 scanner interfaces terminate
to a 10-pin modular jack. The serial # label
indicates the interface enabled when the
scanner is shipped from the factory. Some
units have internal jumpers that can be moved
to enable a different electrical interface.
Current combinations are listed below.
MS7120-9 OCIA
JP1 = Open and JP2 = Closed
MS7120-67 RS-232/LTPN
JP1 = Closed and JP2 = Open
Pin
Function
Function
1
Ground
Ground
2
RS-232 Transmit Output
RS-232 Transmit Output
3
RS-232 Receive Input
RS-232 Receive Input
4
RDATA
RTS Output
5
RDATA Return
CTS Input
6
Clock in
DTR Input/LTPN Source
7
Clock out
Reserved
8
Clock in Return/Clock out
Rtrn
LTPN Data
9
+5VDC
+5VDC
10
Shield Ground
Shield Ground
MS7120-47 Keyboard Wedge
JP1 = Open and JP2 = Closed
MS7120-41 RS-232/LTPN
JP1 = Closed and JP2 = Open
Pin
Function
Function
1
Ground
Ground
2
RS-232 Transmit Output
RS-232 Transmit Output
3
RS-232 Receive Input
RS-232 Receive Input
4
PC Data
RTS Output
5
PC Clock
CTS Input
6
KB Clock
DTR Input/LTPN Source
7
PC +5V
Reserved
8
KB Data
LTPN Data
9
+5VDC
+5VDC
10
Shield Ground
Shield Ground
Continued next page
Options listed are program/cable selections