Warning, Heater selection chart, Caution – Marley Engineered Products RK Series User Manual
Page 2
LIMITED WARRANTY
All products manufactured by Marley Engineered Products are warranted
against defects in workmanship and materials for one year from date of instal-
lation, except heating elements which are warranted against defects in work-
manship and materials for five years from date of installation. This warranty
does not apply to damage from accident, misuse, or alteration; nor where the
connected voltage is more than 5% above the nameplate voltage; nor to equip-
ment improperly installed or wired or maintained in violation of the product’s
installation instructions. All claims for warranty work must be accompanied by
proof of the date of installation.
The customer shall be responsible for all costs incurred in the removal or rein-
stallation of products, including labor costs, and shipping costs incurred to return
products to Marley Engineered Products Service Center.Within the limitations of
this warranty, inoperative units should be returned to the nearest Marley autho-
rized service center or the Marley Engineered Products Service Center, and we
will repair or replace, at our option, at no charge to you with return freight paid
by Marley. It is agreed that such repair or replacement is the exclusive remedy
available from Marley Engineered Products.
THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH
EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DIS-
CLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY
ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL
DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED
UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.
Some states do not allow the exclusion or limitation of incidental or consequen-
tial damages, so the above exclusion or limitation may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
For the address of your nearest authorized service center, contact Marley
Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise
returned to the factory must be accompanied by a return authorization and ser-
vice identification tag, both available from Marley Engineered Products. When
requesting return authorization, include all catalog numbers shown on the prod-
ucts.
INSTALLATION OF ELEMENTS
1. Place heater on flat surface and remove both wiring compart-
ment covers.
2. Remove the outside hex nut from both ends of the element.
3. Place the element in the “L” shaped slots in the heater housing.
4. Install ring terminal on factory installed wire assemblies on the
threaded studs on both sides of element. See Fig. 1.
5. Replace hex nut and secure
6. Replace wiring compartment covers.
APPLICATION LIMITATION AND PRECAUTIONS
•
Hazardous Atmosphere - These heaters are not suitable for
use in hazardous locations.
•
Indoor Use Only
• Ceiling Mount Only - Do not mount to walls.
•
Maintain at least 5’ (1.5 m) in radiant path between bottom of
heater and combustible material.
• Corrosive Atmospheres - The high quality finish and steel
internal sheet metal parts will give excellent service under most
operation conditions, including coastal salt air and most indus-
trial atmospheres. However, the finish is not intended for salt
spay exposure in marine applications or highly corrosive green-
house, swimming pool, chemical storage or industrial atmos-
pheres.
• The mounting structure and anchoring hardware must be
capable of reliably supporting the total weight of the heater and
all accessories.
INSTALLATION OF HEATER
1. Cut suspension chain (approved) to desired mounting length.
2. Attach chain to heater with “S” hooks provided. Heater must
be mounted so that element is horizontal
3. Tilt heater (if desired) by adjusting chains as shown in Fig 2.
WIRING
1. Supply wiring coming to heater must be rated at least 90
degrees C. USE COPPER WIRING ONLY.
2. Rough-in Wiring. Run supply wiring to the heater location
(Check heater nameplate and element for proper supply volt-
age.) Check the amperage of the heater (refer to nameplate on
heater) and verify the supply wiring is properly fused.
3. Wire heaters as shown in Fig. 3.
Fig. 1
Fig. 2
WARNING
SUPPLY WIRING MUST BE SIZED FOR MAXIMUM WATTAGE
OF HEATER WITH QUARTZ TUBE.
!
Fig. 3
HEATER SELECTION CHART
DO NOT HANDLE QUARTZ LAMP OR QUARTZ TUBE HEATING ELEMENTS
WITH BARE HANDS AS SALT IN PERSPIRATION MAY DETERIORATE THE
QUARTZ.
CAUTION
!
Dimensions
Model No.
Volts Watts
Reflective
Height
Width
Length
Wt.
Angle
in. (mm)
in. (mm) in. (mm) lb (kg.)
RK41512
120
1500
RK42020
208
2000
RK42024
240
2000
RK42027
277
2000
46 (1168)
9 (4.1)
RK42034
347
2000
RK42048
380
2000
RK42060
600
2000
60 (Sym)
3.375 (86)
5.5(140)
RK53020
208
RK53024
240
RK53027
277
3000
RK53034
347
57 (1448)
11 (5.0)
RK53048
480
RK53060
600
HOW TO ORDER REPAIR PARTS
In order to obtain any needed repair or replacement parts, warranty service or
technical information, please contact Marley Engineered Products Service Center toll-
free by calling 1-800-642-HEAT.
When ordering repair parts, always give the information listed as follows:
1. The Part Number
2. The Model Number
3. The Part Description
4. Date of Manufacture
Part No. 5200-2395-000
PPD 024
8/00
SPX Corporation
470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA
2
OPTIONAL MECHANICAL ACCESSORIES
Quartz Tube
Ring Terminal
Hex Nut
Model No.
Description
Carton
Wt.
Qty.
lbs (gr.)
WG46
Wire Guard
1
1 (454)
WG57
1.5 (680)
RP-WMB
Wall Mounting Bracket
1
2 (907)