beautypg.com

Troubleshooting, Incorrect connections – Milan Technology MIL-SME801GSX User Manual

Page 149

background image

143

6.

Troubleshooting


This section is intended to help you solve some common problems

encountered while using the MIL-SME801P switch series.

Incorrect connections


The RJ-45 port will auto-detect the signal configuration of the cable. For

10/100 Mbps, only two pairs of wires are required for communications. For

1000Base-TX, all four pairs of wire are required. Some cabling plants may

not have all four pairs, causing a fault in the link.


The fiber port is either a multi-mode or single-mode fiber type. Ensure that

the fiber in the cable matches that of the fiber port.

„

Faulty or loose cables

Look for loose or obviously faulty connections. If they appear to be OK, make

sure the connections are snug. If that does not correct the problem, try

different cables.

„

Non-standard cables

Non-standard and miss-wired cables may cause numerous network collisions

and other network problem. This can seriously impair network performance. A

category 5 cable tester is a recommended tool for every network installation.