background image

PAGE 8 — QP4TZ TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #1 (10/10/08)

CAUTION

NEVER

„

lubricate components or attempt service on a

running machine.

NEVER

„

block or restrict flow from discharge hose.

Remove kinks from discharge line before starting pump.
Operation with a blocked discharge line can cause water
inside pump to overheat.

NOTICE

ALWAYS

„

fill the pump casing with water before starting

the engine. Failure to maintain water inside the pump
housing will cause severe damage to the pump and
mechanical seal.

In winter drain water from pump housing to prevent

„

freezing.

NEVER

„

start the pump with the clean-out cover removed.

The rotating impeller inside the pump can cut or sever
objects caught in it. Before starting the pump, check that
the clean-out cover is securely fastened.

ALWAYS

„

keep the machine in proper running condition.

ALWAYS

„

ensure pump is on level ground before use.

Fix damage to machine and replace any broken parts

„

immediately.

ALWAYS

„

store equipment properly when it is not being

used. Equipment should be stored in a clean, dry location
out of the reach of children and unauthorized personnel.

ENGINE SAFETY

WARNING

NEVER

„

operate the engine with heat shields or

guards removed.

DO NOT

„

remove the engine oil drain plug

while the engine is hot. Hot oil will gush
out of the oil tank and severely scald any
persons in the general area of the pump.

CAUTION

NEVER

„

touch the hot exhaust manifold,

muffler or cylinder. Allow these parts to cool
before servicing equipment.

NOTICE

NEVER

„

run engine without an air filter or with a dirty air

filter. Severe engine damage may occur. Service air filter
frequently to prevent engine malfunction.

NEVER

„

tamper with the factory settings

of the engine or engine governor. Damage
to the engine or equipment can result
if operating in speed ranges above the
maximum allowable.

SAFETY INFORMATION