beautypg.com

Philips Magnavox ELITE ME43BKSP User Manual

Page 21

background image

21

Secure Temp™ ASHT+ High Temp. Insulated Stainless Steel Chimney

8" Diameter, Listed to CAN / UCL-S604 and UL-103HT at 1200° F

Description

Cat./ Part No.

Lengths and Misc. Chimney Components

8" Length, 8" Dia., 8L8

8L8

12" Length, 8" Dia., 8L12

8L12

18" Length, 8" Dia., 8L18

8L18

24" Length, 8" Dia., 8L24

8L24

36" Length, 8" Dia., 8L36

8L36

48" Length, 8" Dia., 8L48

8L48

Adjustable Length 12", 8" Dia., 8LA

8LA

15° Elbow, 8" Dia., 8E15

8E15

30° Elbow, 8" Dia., 8E30

8E30

Rain Termination Cap, 8" Dia., 8CC

8CC

Wall Band, BM

BM

Supports

Offset Support, SO

SO

Roof Support, ST

ST

Roof Brace, BS2

BS2

Firestops

Telescopic Attic Radiation Shield, 8ARSA

8ARSA

Firestop, 8BF

8BF

Radiation Shield, 8RS

8RS

Insulated Attic Radiation Shield, 8RSA

8RSA2

Insulated Wall Radiation Shield, 8RSM

8RSM

Roof Flashings

Flat Roof Flashing, 8FR

8FR

1/12 - 7/12 (5º - 30º), 8FAR

8FAR

8/12 - 12/12 (30º - 45º), 8FBR

8FBR

Storm Collar, 8FC

8FC

COMPONENTS LIST - ME43

AC Chimney

(Air Cooled - 8" I.D., 13" O.D.)

Description

Cat./ Part No.

AC Starter Adaptors

An AC Adaptor is Need to Convert Fireplace for Use with AC Chimney

Starter Section (adaptor), 8" AC, AC8SB

H3801

Starter 30º Elbow, 8" AC, AC8SB30

H3802

Outside Air Kit

Required for AC Chimney Installations

Chimney Outside Air Kit (flex, insulation, outside register

and coupling), ACZI

H1967

Lengths and Misc. Chimney Components

18" Length, 8" Dia. x 18" Long, AC8L18

H3798

36" Length, 8" Dia. x 36" Long, AC8L36

H3799

48" Length, 8" Dia. x 48" Long, AC8L48

H3800

15º Elbow, 8" Dia., AC8E15

H3795

30º Elbow, 8" Dia., AC8E30

H3796

Rain Termination Cap, 8" Dia., AC8CPR

H3794

Spark Arrester Screen (universal spark arrester band)

PE+

PE

Wall Band, XBM

XBM

Supports

Offset Support, SO

H0480

Support Section, AC8SL

H3804

Roof Support, ST

H0482

Roof Brace, BS2

H0483

Room Flashings

Flat Roof Flashing, ACF

H0494

1/12 - 7/12 (5º - 30º), AC, Adj. Roof Flashing, FA

H0495

8/12 - 12/12 (30º - 45º), AC, Adj. Roof Flashing, FB

H0496

Storm Collar, ACFC

H0500

Misc.

Telescopic Attic Radiation Shield, ACRST

H0498

Firestop, ACBF

H0485

Radiation Shield, ACRS

H0486

Attic Radiation Shield, ACRSA

H0487

Wall Radiation Shield, 30, AC, RSM30

ACRSM30

Insulated Wall Radiation Shield, 30, ACRSMI30

H0489

Notes: AC Chimney is Not recommended at elevations above 4000 feet or

in cold climates.