INSULATED

FLEX PIPE

CENTRAL FORCED AIR KIT

The knock-outs provided on the sides of the

ME43 fireplace allow the connection of insulated

flexible pipe which enables you to heat adjacent

rooms up to 50 feet from the fireplace.

The ducting system must be installed as de-

scribed below :

1. Fix the adaptor at the side of the fireplace by

twist-locking the adaptor to the fireplace.

You can use more than one outlet on the

fireplace (Figure 11).

2. Attach the 5" flexible pipe, using the col-

lars provided. Important: Make sure that

the plastic wrapping around the flexible

pipe will not be in contact with the fire-

place.

3. Route the flexible pipe to the chosen loca-

tion. The ducting system can be installed

either in an upper room or in a lower

room.

4. Attach the flexible pipe to the blower, using

the collars (Figure 12).

5. Fix the decorative grill blower adaptor to

the blower.

6. Attach a standard 3" x 10" grill to the

adaptor.

7. Install the blower thermostat in that part

of the house to be heated by the hot air

duct. Do not install the blower thermostat

in the room where the fireplace is located.

A cooling thermostat can be installed in the

same room as the unit. This thermostat

will turn on the blower when the room

where the fireplace is located becomes

too hot.

This option requires electricity. Make sure that

the connections to the blower have been made

according to the local codes and comply with

their requirements. It is possible to connect

a flexible pipe to a central heating system.

Make sure the pipe will be connected to the

warm air supply duct, not to the return air

duct (Figure 13). Contact your local furnace

installer for installation guidelines.

Chase Enclosure

A chase is a vertical box-like structure construct-

ed to surround the fireplace and chimney. Refer

to Figure 14 for a typical chase configuration.

As with all chimney installations, avoid overhead

obstructions such as trees, power lines, etc.

A chase should be constructed and insulated

just like any outside wall. In a cold climate, we

recommend the base of the chase should also

be insulated between the solid continuous floor

beneath the fireplace and the chase bottom.

Chase insulation in a cold climate installation

is not required for safety.

Figure 12

Figure 13

INSULATION

FAN

ALUMINUM TAPE

COLLAR

FLEX 5” O

5” O

INSULATED FLEX

FAN

FURNACE

AIR FLOW

NO-RETURN
VALVE