Relays, Timers, and Sensor Input Class

Ordering Your Configuration

Sensor Input

Specify Class

Specify Function

Default Nomenclature

User Specified Nomenclature

Example:

Class B2

SD

Compressor Oil Pressure

Compressor #1 Oil Pressure

Input 1

____________

_________________

Compressor Oil Pressure

________________________

Input 2

____________

_________________

Compressor Oil Level

________________________

Input 3

____________

_________________

Lubrication No-Flow

________________________

Input 4

____________

_________________

Low Suction Pressure

________________________

Input 5

____________

_________________

Interstage Pressure #1

________________________

Input 6

____________

_________________

Interstage Pressure #2

________________________

Input 7

____________

_________________

Interstage Pressure #3

________________________

Input 8

____________

_________________

Discharge Pressure

________________________

Input 9

____________

_________________

Discharge Temperature #1

________________________

Input 10

____________

_________________

Discharge Temperature #2

________________________

Input 11

____________

_________________

Discharge Temperature #3

________________________

Input 12

____________

_________________

Discharge Temperature #4

________________________

Input 13

____________

_________________

Suction Liquid Level

________________________

Input 14

____________

_________________

Interstage Liquid Level #1

________________________

Input 15

____________

_________________

Interstage Liquid Level #2

________________________

Input 16

____________

_________________

Interstage Liquid Level #3

________________________

Input 17

____________

_________________

Inlet Scrubber Liquid Level

________________________

Input 18

____________

_________________

Engine Oil Pressure

________________________

Input 19

____________

_________________

Engine Oil Level

________________________

Input 20

____________

_________________

Engine Oil Vibration

________________________

Input 21

____________

_________________

Engine Jacket Water Temp.

________________________

Input 22

____________

_________________

Engine Jacket Water Level

________________________

Input 23

____________

_________________

Engine Jacket Water Press.

________________________

Input 24

____________

_________________

Engine Vacuum Right Bank

________________________

Input 25

____________

_________________

Engine Vacuum Left Bank

________________________

Input 26

____________

_________________

Compressor Vibration

________________________

Input 27

____________

_________________

Cooler Vibration

________________________

Input 28

____________

_________________

Cooler Water Level

________________________

Input 29

____________

_________________

Auxiliary Pump Shutdown

________________________

Input 30

____________

_________________

Emergency Shutdown

________________________

Input 31

____________

_________________

PLC Shutdown

________________________

Input 32

____________

_________________

Prelube Permissive

________________________

Use the listings below to specify sensor input Class, Function and Nomenclature; the S1500 sensor inputs are factory-configured as follows:

Class A: Armed at all times for alarm or shutdown (specify).

Class P: Locked out by the Compressor Load lockout timer.

Class B1: Locked out by first lockout timer (First Start/Run timer).

ESD: Overrides the Test lockout timer (for Remote/Emergency Stop input).

Class B2: Locked out by second lockout timer (Second Start/Run timer).

SD: S1500 System Shutdown Function.

Class C: Armed after fault condition has been cleared for 2 seconds.

AL: Alarm Relay Function (no shutdown).

Select your Relay Logic Mode (see page 4):

MODE No. ____________________

Select your Timing and range; (default values)

TACHOMETER

Pulses/Rev.: _____________________ (60)

Crank Disconnect: _______________ (100)

Underspeed: ____________________ (150)

Overspeed: _____________________ (400)

TIMERS

Prelube: ___________________ (0:30)

Run Delay: _________________ (0:30)

Class B1: ___________________ (1:00)

Class B2: ___________________ (1:00)

Load Delay: _________________ (1:00)

Process Delay: _______________ (1:30)

Idle/Cooldown: _______________(5:00)

Ignition Ground: _______________ (0:10)

Postlube: ______________________ (0:30)

CRANKING

Attempts: ______________________ (5)

Crank Period: __________________ (0:15)

Rest Period: ____________________ (0:15)