beautypg.com

Miller Electric CP-202 User Manual

Page 17

background image

OM-259 Page 13

2-7.

Inductance Selection (200 And 300 Ampere Models)

1

Stabilizer Z

Tapped stabilizer Z is factory
connected to the stabilizer tap
which suits most GMAW
applications.

Stabilizer Z controls the inductance
applied to the weld current. To in-
crease inductance and wet out the
weld puddle, connect to stabilizer Z
ending.

To change inductance proceed as
follows:

2

Lead 25

3

Stabilizer Z Tap

4

Stabilizer Z Ending

5

Lead 26

To increase inductance, connect
lead 26 to stabilizer ending and
secure.

Reinstall side panel.

6

Typical Weld Bead Using The
Tap Stabilizer Connection

Use the tap Stabilizer connection to
obtain arc type and weld bead suit-
able for some mild steel applica-
tions.

7

Typical Weld Bead Using The
End High Stabilizer
Connection

Use the end Stabilizer connection
to reduce weld bead crowning, and
spread the weld puddle.

ST-801 379-B

3/8, 7/16 in

3/8 in

1

2

3

4

5

6

7

Weld Bead Using The Tap Stabilizer

Connection With 17 Volts, 100 Amps

Weld Bead Using The End Stabilizer

Connection With 17 Volts, 100 Amps