Ttl, rs232, 3.3v / 5v (77-77142), Ttl, rs232 3.3v / 5v – Metrologic Instruments IS4823 User Manual
Page 32

28
TTL, RS232, 3.3V / 5V
12-Pin ZIF Connector
Pin
Signal Name
Function
1
TTLINV
Input: TTL RS232 Polarity Control with 33.2k ohm Pull-Up
2
+3.3V or 5.0V Power: Supply Voltage Input, +3.3V ± 0.3V or +5.0V ± 5%
3
GND
Ground: Power and Signal Ground
4
RxD
Input: TTL Level RS232 Receive Data
5
TxD
Output: TTL Level RS232 Transmit Data
6
CTS
Input: TTL Level Clear to Send
7
RTS
Output: TTL Level RS232 Request to Send
8
PWRDWN
Output: Active High = IS4823 is in Power Down Mode
9 nBEEPER
Output: Active Low, Signal Capable of Sinking Current
See Detailed Electrical Specifications starting on page 23.
10 nGood
Scan
Output: Active Low, Signal for Sinking Current (Good Scan)
See Detailed Electrical Specifications starting on page 23.
11 nEXT
WAKE
Input: Active Low, Signal Used to Bring Engine Out of
Power Down
12 EXT
Trig
Input: Active Low, Signal Used as Trigger Input to Activate
the Engine
10-Pin ZIF Connector
Pin
Signal Name
Function
1 SDA
I
2
C Data (Bi-Directional) – Devices Function as Auxiliary
Devices
2
GND
Ground: Power and Signal Ground
3
GND
Ground: Power and Signal Ground
4 Scan
Sense
Level changes from High to low or low to high when the
laser changes direction at the start of the scan line
High = Bar
5 Data
Low = Space
High = Engine OFF
6 Scan
Enable
Low = Engine ON
High = Laser OFF
7 Laser
Enable
Low = Laser ON
8 NC
No
Connection
9
+3.3V or 5.0V Power: Supply Voltage Input, +3.3V ± 0.3V or +5.0V ± 5%
Figure 20.
10 SCL
I
2
C Data (Bi-Directional) – Devices Function as Auxiliary
Devices