beautypg.com

Common coffee system care – Miele CVA 2650 User Manual

Page 42

background image

The right display goes dark and the
appliance is now lowering the
perforator.

Remove capsule plate and

change the capsule hopper

^ Open the appliance door.

^ Pull out the capsule plate.

,

Do not reach up into the

perforator opening. Danger of injury!

^ Pull the rubber disc top, down and

out.

^ Insert the tool for removing the

perforator up into the unit, a. Turn it
to the left, b, to loosen and remove
the perforator.

^ Screw the new perforator firmly into

the unit. The spring and ball bearing
must be inserted in the perforator
opening so that the ball bearing is on
top.

^ Insert the rubber disc from the

bottom up (with the funnel pointing
downwards).

^ Insert the capsule plate and close the

door.

Common coffee system care

42