5. Then select the Major Revision level of the ENBT firmware. In the Verification System, the major

revision level of the ENBT module is 2.

6. Enter the proper Name, Slot Location, Revision Level and IP Address of the ENBT module. In the

Verification System, the module name is set at CSC_EIP, the revision firmware level is 2.3, the
module is in Slot 1 of the ControlLogix Chassis, and the IP address is set at 192.168.1.30, matching
the previous configuration.