Error Code
Probable Cause
12
No error detected
22
Recovery from momentary Reset
32
Lamp Cover open
33
Air Filter Cover open
34
Lamp abnormality
35
Chassis Fan failure
36
Exhaust (Back Cover) or Lamp Ballast Fan failure
37
Engine (DMD or Lamp) Fan failure
38
Excess Lamp Temperature
39
Excess DMD Temperature
41
Short Detected
44
DVI Cable (between Chassis and Engine) disconnected
ERROR CODES
Press and Hold "DEVICE" and "MENU" FOR 5 SECONDS
3. Error Code Operational Check
Note: The TV must be in “Shut Down” and not manually switched Off, to perform the Error Code Opera-
tional Check. When the TV is switched Off, the code automatically resets to “12” No Error.
Press the front panel “DEVICE” and “MENU” buttons at the same time, and hold for 5 seconds to
activate the Error Code Operational Check. The LED will then flash denoting a two digit Code.
Note: The front panel buttons must be used, NOT those on the Remote Control.
•
The number of flashes indicates the value of the MSD (tens digit) of the Error Code.
•
The flashing then pauses for approximately 1/2 second.
•
The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.
Example: If the Error Code is “32”, the LED will flash three times, pause, and then flash two times.
•
The Error Code is repeated a total of 5 times.
4. Error Codes
The Error Code designations are listed below: