beautypg.com

Manual co2 inflation device, Beaded co2 inflation handle, Manual co – Mustang Survival MSV971 User Manual

Page 9: Inflation device, Beaded co, Inflation handle, Figure 5. manual co, Inflation device – non-operated/ready position, 5 manual co

background image

Mustang Survival MSV971 Life Preserver and Survival Vest

Description and Maintenance Instructions

9 June 2004, Rev: 1.0



2.5

MANUAL CO

2

INFLATION DEVICE

The MSV971 is an appropriate platform for a wide variety of customized LP/SV units to address user
requirements that include:

• use in ejection seat fitted aircraft
• use with an automation inflation device
• stowage of unique pieces/combinations of survival equipment

Contact Mustang Survival for further details.

2.5.1

Life preservers, which are intended for use in non-ejection seat, equipped aircraft incorporate
a manually operated inflation device. The operating components of the manual inflation device
(Halkey-Roberts HD77189 840 AMLS INFLATOR) are shown in figure 5.

Figure 5. Manual CO

2

Inflation Device – Non-Operated/Ready Position

CO2 Cylinder

Manual Inflator

Lever in Up and
Ready Position

Green Indicator Pin

Pull-tab

2.5.2

2.6.1

The manual inflation device is located on the rear left lobe of the inflatable cell. The inflation
device is secured with a cap nut to the manifold valve, which in turn is RF bonded to the
inflatable cell. A 34-37 gram carbon dioxide (CO

2

) cylinder is threaded into the top of the

inflation device, and is secured against the cell with a looped nylon elastic retaining strap. The
beaded inflation handle is attached with a lanyard to the operating lever of the inflation device,
which in turn is safety tied by inserting and tying a red cotton witness thread through the hole
in the operating lever and through the hole in the body of the inflation device.

2.6

BEADED CO

2

INFLATION HANDLE

The beaded inflation handle is constructed of six plastic beads threaded onto a loop of nylon
webbing. The handle is attached with a lanyard to the operating lever of the CO

2

inflation

device and is fixed with Velcro™ to the back side of the left lobe of the protective container.

6

T

T

h

h

i

i

s

s

d

d

o

o

c

c

u

u

m

m

e

e

n

n

t

t

i

i

s

s

f

f

o

o

r

r

i

i

n

n

f

f

o

o

r

r

m

m

a

a

t

t

i

i

o

o

n

n

p

p

u

u

r

r

p

p

o

o

s

s

e

e

s

s

o

o

n

n

l

l

y

y

.

.

I

I

t

t

i

i

s

s

n

n

o

o

t

t

a

a

c

c

o

o

n

n

t

t

r

r

o

o

l

l

l

l

e

e

d

d

d

d

o

o

c

c

u

u

m

m

e

e

n

n

t

t

a

a

n

n

d

d

m

m

a

a

y

y

n

n

o

o

t

t

b

b

e

e

c

c

o

o

n

n

s

s

i

i

d

d

e

e

r

r

e

e

d

d

c

c

u

u

r

r

r

r

e

e

n

n

t

t

w

w

h

h

e

e

n

n

p

p

r

r

i

i

n

n

t

t

e

e

d

d

.

.