22

CDVX Series Direct Vent Gas Fireplace

20012253

How to Use the Vent Graph

The vent chart should be read in conjunction with the
following vent installation instructions to determine the
relationship of the vertical and horizontal dimensions of
the vent system.
1. Determine the height of the center of the horizontal

vent pipe exiting through the outer wall. Using this
dimension on the Sidewall Vent Graph (Fig. 42),
locate the point intersecting with the slanted graph
line.

2. From the point of this intersection, draw a vertical

line to the bottom of the graph.

3. Select the indicated dimension, and position the

fireplace in accordance with same.

Example A:
If the vertical dimension from the floor of the fireplace
is 11’ (3.4 m) the horizontal run to the face of the outer
wall must not exceed 14’ (4.3 m).
Example B:
If the vertical dimension from the floor of the unit is 7’
(2.14 m), the horizontal run to the face of the outer wall
must not exceed 8¹⁄₂’ (2.6 m).

36CDVXT Vertical Venting

Horizontal dimension from the outside face of the

wall to the center of the fireplace vent flange

Sidewall vent graph showing the relationship between vertical

and horizontal dimensions for a Direct Vent flue system.

V

ertical dimension from the fl

oor of the unit

to the center of the horizontal vent pipe

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

eg: A

eg: B

CFM102

DV Graphic

9/28/00 sta

Fig. 42 Sidewall venting graph. (Dimensions in feet)

36 CDVXT Top Vent Baffle

The 36CDVXT is shipped with a restrictor installed in
the unit. This allows for a better flame when installing a
vertical venting configuration. Below is a rough esti-
mate of opening positions based on vent length. This
is a guide. More fine tuning can be done by a qualified
installer. Adjust the restrictor so there is no lifting of the
flame from the burner tube and the flame is not dirty to
create soot.
To adjust:
1. Loosen the two (2) screws securing the flue baffle.

(Fig. 43)

2. Remove two (2) screws from either side of the flue

box. (Fig. 43) Adjust the restrictor. (Fig. 44)

3. Tighten the screws in the flue baffle and insert the

two (2) screws removed earlier through the slots in
the restrictor.

������
������������
�����

Loosen

Screws

Flue Baffle

Flue Pipe

FP1797

Fig. 43 Loosen screws securing flue baffle.

Remove Screws

from Either side

Flue Box

X

FP1799
CDVXT restrictor
4/07

Restrictor

FP1799

Fig. 44 Adjust the restrictor for best flame appearance.

Up to 10’ (3 m) X = 1¹⁄₂” (38 mm)
10’ to 40’ (12 m) X = 1¹⁄₄” (32 mm)