beautypg.com

Miller Electric XMT 456 CC User Manual

Page 32

background image

OM-203 034 Page 28

6-3. Removing Case and Measuring Input Capacitor Voltage

Turn Off welding power source, and

disconnect input power.
1

Outside Handle Screws

To loosen top, remove two outside

handle screws from both handles

and all side bolts.
2

Interconnecting Board PC2

3

Voltmeter

Measure the dc voltage across the

screw terminals on RC3 and RC5

as shown until voltage drops to near

0 (zero) volts.
Proceed with job inside unit. Rein-

stall cover when finished.

Tools Needed:

5/16 in

802 260 / 801 536

2

3

+ lead to lower right

terminal, − lead to

upper right terminal

1

1

!

Significant DC voltage can remain on capac-

itors after unit is Off. Always check the volt-

age as shown to be sure the input capacitors

have discharged before working on unit.

This manual is related to the following products: