5-7. Lift-Arc TIG Procedure For CC/CV Models

With Mode switch in the Lift-Arc TIG

position, start an arc as follows:
1

TIG Electrode

2

Workpiece

Touch tungsten electrode to work-

piece at weld start point, hold

electrode to workpiece for 1-2

seconds, and slowly lift electrode.

An arc will form when electrode is

lifted.
Normal open-circuit voltage is not

present before tungsten electrode

touches workpiece; only a low

sensing voltage is present between

electrode and workpiece. The

solid-state output contactor does

not energize until after electrode is

touching workpiece. This allows

electrode to touch workpiece with-

out overheating, sticking, or getting

contaminated.

1

1 − 2

Seconds

“Touch”

Do NOT Strike Like A Match!