beautypg.com

Multitech MULTIMODEM MT5634ZBA-USB User Manual

Page 34

background image

34

MT5634ZBA-USB User Guide

Register

Unit

Range

Default

Description

S42

decimal

0–1

1

Enables/disables the 56K auto rate. When
56K auto is disabled, fallback to V.34 is also
disabled. 0 = disable; 1 = enable.

S43

decimal

0–1

1

For testing and debugging only. Enables/
disables V.32bis start-up auto mode operation.
0 = disable; 1 = enable.

S48

decimal

7 or 128 7

Enables (7) or disables (128) LAPM
negotiation. The following table lists the S36
and S48 configuration settings for certain
types of connections.

S48=7

S48=128

LAPM or async

Async

LAPM or hangup

Do not use

LAPM, MNP, or aysnc

LAPM, MNP, or hangup

MNP or hangup

MNP or async

S36=0, 2

S36=1, 3

S36=4, 6

S36=5, 7

S89

seconds 0, 5–255 10

Sets the length of time in the off-line command
mode before the modem goes into standby
mode. A value of zero prevents standby mode;
a value of 1–4 sets the value to 5.

S109

decimal

0, 1 or 2 1

Selects one of three 56K operating modes.
0

V.90 disabled

1

K56flex or V.90 (dual-mode
enabled)

2