2. Remove parts inside the refrigerator
(1) Remove chilled case door and slide chilled case ,
remove crystal shelf of refrigerator room , remove the
control panel
(Photo 6)
(2) Remove lamp cover R
(Photo 6)
(3) Remove screw and rivet , pull the control panel with
to right refrigerator wall.
(Photo 6)
(4) Pick the aluminium tape and sealing tape, remove
PC Board
(Photo 7)
(5) Remove duct R assy, damper thermo is installed
within it.
(Photo 7)
Remove the screw of damper thermo
Caution on assembly
1. Be sure to use new sealing materials and tape for
assembly.
- 21 -
OPERATION PROCEDURE
PHOTO
2. Attach the sealing material of refcon assy and attach
the aluminium tape everytimes for protective moisture.
Photo 6
Photo 7
Rivets
Thermo dial R
Lamp cover R
Screws
Control panel
Thermo dial F
Aluminium tape
Duct R assy
Sealing tape
PC Board