Command list

Settings:

38.4K baud, 1 stop bit, no parity

Format: ! or !Vxx.x

The '!' is used as a framing character and can be sent any time to reset the
packet reception code. Note that all commands are 5 bytes ( '!' + 3char command
+ ) with the exception of the direct volume command which is 7 bytes ( '!' +
'V' + 4 bytes data + ) = 0x0d, carrage return.

Example:

!GI1 ( selects input 1 on No320S)

Keys:

COMMAND DESCRIPTION

KVD

Volume "key" down

KVU

Volume "Key" up

KBA

Balance Key

KSU

Setup Key

KEN

Enter Key

KST

Standby Key

KMU

Mute Key

KMO

Mono Key

KIP

Input select previous "key"

KIN

Input select next "key"

KPO

polarity key

KDI

Display Intensity key

Note on ramping volume:

Repeated “EV_VOL_DOWN” or “EV_VOL_UP” key commands must be

sent at less than 150mS intervals to cause a smooth, accelerated ramping of
volume like the effect of holding the volume up or down key on the remote
control.

Directs:

COMMAND DESCRIPTION

GOP

Go to Operate mode

GST

Go to Standby mode

GMU

Go to mute

GMN

Restore volume

GI1