Maytag Epic W10139629A User Manual
Page 15
15
2. Place the hooked end of the neutral wire (white or center wire) of direct wire cable under
the center screw of terminal block (hook facing right). Squeeze hooked end together.
Tighten screw.
3. Place the hooked ends of the other direct wire cable wires under the outer terminal block
screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
down screw.
6. You have completed your electrical connection. Now go to “Venting Requirements.”
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do not permit connecting
cabinet-ground conductor to neutral wire.
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor screw. Connect neutral
ground wire and the neutral wire (white or center wire) of power supply cord/cable under
center, silver-colored terminal block screw. Tighten screw.
3. Connect the other wires to outer terminal block screws. Tighten screws.
4. Tighten strain relief screws.
5. Connect a separate copper ground wire from the external ground conductor screw to an
adequate ground.
6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
down screw.
A. External ground conductor screw
B. Neutral ground wire
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E.
³⁄₄
" (1.9 cm) UL listed strain relief
A
C
D
B
E
A. External ground conductor screw
B. Center silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E.
³⁄₄
" (1.9 cm) UL listed strain relief
F. Grounding path determined by a qualified electrician
A
B
C
D
F
E