beautypg.com

Moxa Technologies C168P User Manual

Page 74

background image

6-6

C168P User’s Manual

c. The I/O addresses may conflict with other devices, please change another set

of I/O address such as I/O:0x280, Interrupt Vector:0x2C0.

d. The board(s) is not plugged properly. Please make sure the board is seated

firmly in the expansion slot.

e. The slot for plugging the board is defective.

In this case, please try other slots until you find a good one.

f. The board might be defective.

DOS

This section is specific for troubleshooting under DOS. For general problems and
solutions, please see the previous section, “General Troubleshooting”.

1. After executing SER-DRV.EXE, error message “None serial port found!”

appears.

a. Make sure you’re using the right driver.
b. Check if the board is properly plugged into ISA/EISA bus slot.

c. Check if the I/O address and IRQ settings in SETUP program are same as

the settings on board.