Operational
Depth of Scan Field:
254 mm to 559 mm (10" to 22")
Scan Speed:
1,250 scan lines per second
Scan Pattern:
25 line omnidirectional
Exit Angle:
12° down off perpendicular of scan window
Indicators:
LED: red = good read; green = laser on
Beeper Operation:
Selection of 3 tones for “Good Read”
Maintenance Required:
Clean window periodically
Decode Capability:
Autodiscriminates
System Interfaces:
RS232C; Light Pen Emulation; OCIA; RS422
Print Contrast:
35% minimum reflectance difference
Roll, Pitch, Yaw:
360°, 60°, 60°
Environmental
Storage Temperature:
-40°C to 60°C (-40°F to 140°F)
Operating Temperature:
0°C to 35°C (32°F to 95°F)
Humidity:
5% to 95% relative humidity, non-condensing
Light Levels:
Up to 3200 foot candles - works in direct sun
Ventilation: None
required
Shock:
100 g for 1 ms
ESD:
8 kV IEC 801-2
Contaminants:
Protects against dust, falling dirt, and dripping non-corrosive liquid
Specifications subject to change without notice.
10