Marvel Industries 60RDE User Manual

Page 9

background image

Sen

tr

y S

ys

tem™ “Basic” Function “

Quick” R

ef

er

ence

Not

e:

All k

eypad pr

esses ar

e c

on

firmed with an audible t

one when r

eleased.

Function

Function Access

Con

tr

ol Con

firma

tion / Commen

t

Turn Unit On & Off

Pr

essing and holding the “

On/Off

” k

ey f

or fiv

e sec

onds will turn the unit “

ON” or

“Off

”.

The displa

y will be blank when the r

efrig

er

ation s

ys

tem is off

. Ligh

ts will s

till function, but will

time-out in 15 minut

es a

ft

er each activ

ation if dr

aw

er is le

ft open, t

o pr

ev

en

t o

verhea

ting.

Adjus

t and Vie

w T

emper

atur

e

se

t-poin

t

To adjus

t the t

emper

atur

e se

t-poin

t, pr

ess the “SET

” k

ey and curr

en

t se

t-poin

t will

be displa

yed. Use the “

W

ARMER” or “C

OLDER” k

ey

s t

o adjus

t se

t-poin

t t

emper

a-

tur

e.

“SET

” will appear in t

emper

atur

e displa

y when in se

t-poin

t mode. “SET

” mode will aut

oma

ti-

cally time-out in t

en (10) sec

onds if no k

eypad activity occur

s, or y

ou ma

y e

xit “SET

” mode

by pr

essing the “SET

” k

ey .a sec

ond time.

Displa

y “

Actual” T

emper

atur

e

The displa

y r

epr

esen

ts r

eal time monit

oring. Some t

emper

atur

e fluctua

tion ar

ound

the se

t-poin

t will be noticeable as the r

efrig

er

ation s

ys

tem cy

cles on and off t

o

main

tain the desir

ed t

emper

atur

e.

Temper

atur

e

varia

tion in

“c

ompartmen

t” air

, abo

ve

and

belo

w se

t-poin

t,

is a no

rmal e

ffect

of

re

frig

er

ation s

ys

tem cy

cling on and off

. St

or

ed it

ems will not e

xperience the full t

emper

atur

e

swing of the c

ompartmen

t air due t

o the dampening e

ffect of their thermal mass.

Select °F or °C Displa

y

Pr

essing the “°F

/°C

” k

ey will t

og

gle the displa

y be

tw

een F

ahr

enheit and Cen

tigr

ade

temper

atur

e displa

y.

i.e. 55°F = 13°C

Sabba

th Mode

Pr

ess and hold the “SET

” k

ey while pr

essing the “°F

/°C

” k

ey f

our (4) times in se

ven

(7) sec

onds.

The displa

y will flash “S

A” se

ven (7) times, then the unit will en

ter Sabba

th Mode. The

displa

y, audible alarms, LED

, and ligh

ts will be disabled. Sabba

th Mode will aut

oma

tic

ally

time-out in 72 hour

s., or c

an be e

xit

ed b

y r

epea

ting the enabling pr

ocess.

Sen

tr

y S

ys

tem™ alarms

No action r

equir

ed. S

ys

tem monit

oring is aut

oma

tic

ally enabled unless s

ys

tem has

been disabled (see belo

w).

Sen

tr

y S

ys

tem™ LED displa

ys a s

teady gr

een when Sen

tr

y S

ys

tem™ is enabled.

Dr

aw

er Ajar Alarm

No action r

equir

ed if Sen

tr

y S

ys

tem™ is enabled.

Audible alarm will sound 3 times e

ver

y 30 sec

onds, the LED will flash gr

een. Close dr

aw

er t

o

rese

t alarm.

High/Lo

w T

emp Alarm

No action is r

equir

ed if Sen

tr

y S

ys

tem™is enabled. NO

TE: This alarm ma

y occur

when changing se

t-poin

ts and/

or high usag

e, this is normal.

Alarm will sound 6-times e

ver

y minut

e and LED will flash r

ed if pr

oduct t

emper

atur

e e

xcur

-

sions occur f

or a dur

ation outside accep

table limits.

Po

w

er F

ailur

e Alarm

No action r

equir

ed if Sen

tr

y S

ys

tem™is enabled. NO

TE: Alarm will occur upon initial

ins

talla

tion, since unit w

as run a

t the f

act

or

y t

o v

erif

y quality

, this is normal.

LED will flash amber whene

ver po

w

er is in

terrup

ted t

o unit. Ther

e is no audible signal. Pr

ess

ON/OFF butt

on t

o r

ese

t alarm.

Rese

t Alarms

Close dr

aw

er t

o r

ese

t “DOOR A

JAR” alarm. Pr

ess the “

ON/OFF

” k

ey t

o r

ese

t all

other alarms.

Not

e tha

t although pr

essing the “

ON/OFF

” k

ey r

ese

ts the alarms, the alarm will r

esume if

the “

alarm c

ondition” s

till e

xis

ts.

Enable / Disable Sen

tr

y

Sy

st

em™alarms

Pr

ess and hold the “SET

” k

ey f

or fiv

e (5) sec

onds t

o enable or disable the Sen

tr

y

Sy

st

em™ alarms.

LED displa

ys a s

teady gr

een when alarms ar

e enabled. LED displa

ys a s

teady amber when

the

y ar

e disabled.

8