Marvel Industries 60RDE User Manual

Page 10

background image

Sen

tr

y S

ys

tem™ “

Tr

oubleshooting

” Function “

Quick” R

ef

er

ence

Not

e:

All k

eypad pr

esses ar

e c

on

firmed with an audible t

one when r

eleased.

Function

Function Access

Con

tr

ol Con

firma

tion / Commen

t

Sho

w R

oom Mode

Enable the sho

wr

oom mode b

y pr

essing and holding the “

ON/OFF

” k

ey while

perf

orming a “P

ow

er On R

ese

t” (POR). i.e. disc

onnect and r

ec

onnect the po

w

er

supply t

o the unit. Exit Showr

oom Mode b

y initia

ting a POR only

.

Sho

w R

oom Mode will disable the r

efrig

er

ation s

ys

tem and f

ans while allo

wing the

in

ternal ligh

ts, displa

y, and user in

terf

ace panel t

o function. Ligh

ts will time-out

aft

er 15 minut

es of c

on

tinuous on-time while in Sho

w R

oom Mode as a sa

fe

ty

fea

tur

e. The 15 minut

e ligh

t on time c

an be r

eactiv

at

ed b

y closing and opening the

door or b

y pr

essing the “LIGHT

” k

ey

.

Err

or Codes

E1

Compr

essor f

ault, (high/lo

w amp

s)

E2

Condenser f

an mot

or f

ault, (high/lo

w amp

s)

E3

Ev

apor

at

or thermis

tor “

sensor B” f

ault, (out of r

ang

e)

E4

Displa

y thermis

tor “

sensor A

” f

ault, (out of r

ang

e)

Please c

all a qualified ser

vice t

echnician if an

y of these c

odes ar

e displa

yed.

Ser

vice Diagnos

tics

To en

ter and e

xit Ser

vice Diagnos

tics Mode, pr

ess and hold the “

W

ARMER” k

ey

while pr

essing the “C

OLDER” k

ey f

our (4) times in fiv

e (5) sec

onds. Ser

vice Diag

-

nos

tics Mode will aut

oma

tic

ally e

xit a

ft

er fiv

e (5) minut

es of no k

eypad en

tr

y.

Displa

y Err

or Code R

ef

er

ence:

The micr

opr

ocessor in the c

on

tr

ol c

on

tinually monit

or

s critic

al r

efrig

er

ation s

ys

-

tem c

omponen

ts f

or pr

oper oper

ation. If c

omponen

t par

ame

ter

s e

xceed normal

oper

ation specific

ations, the displa

y will aut

oma

tic

ally flash the r

espectiv

e err

or

code as f

ollo

w

s:

Ser

vice Diagnos

tics Mode enables ser

vice t

echnicians t

o iden

tif

y the firm

w

ar

e and

softw

ar

e v

er

sions, t

es

t s

ta

tus of “model specific” s

ys

tem c

omponen

ts and sensor

s,

and chang

e s

ta

te of c

omponen

ts wher

e applic

able, (i.e. -c

ompr

essor “

ON/OFF

et

c.). While in Ser

vice Diagnos

tics Mode, t

es

ts ar

e incr

emen

ted b

y pr

essing the

“SET

” k

ey and specific c

omponen

t s

ta

te c

an be chang

ed t

o “

on” or “

off

” b

y pr

essing

the “

W

ARMER” or “C

OLDER” k

ey

s r

espectiv

ely

. The f

ollo

wing c

omponen

t t

es

ts ar

e

av

ailable:

A

vailable St

atus Indic

at

or

s

Tes

t #

Componen

t Descrip

tion

OK

Off/

Open

On/

Short

ed

0

Temper

atur

e Sensor

, Upper

0-

00

01

1

Temper

atur

e Sensor

, Lo

w

er

1-

10

11

2

Compr

essor

n/

a

20

21

3

In

terior / Ice Mak

er F

an

n/

a

30

31

4

Re

ver

se Gas Solenoid

n/

a

40

41

5

Condenser F

an

n/

a

50

51

6

Mullion Hea

ter

n/

a

60

61

7

Door A Sense

n/

a

70

71

8

Door B Sense

n/

a

80

81

9

Door C Sense

n/

a

90

91

NO

TE: The Door Sense is loc

at

ed be

tw

een the Upper Compartmen

t Displa

y and the

“ON/OFF

” k

ey and c

an be t

es

ted with an

y magne

t.

Door sense “C

” (T

es

t #9) is in the menu but not a

vailable on dr

aw

er units.

9