Mechanical
Parameter
Value
Comment
Size
3.9”” x 1.2” x 1.0”
(99mm x 30.5mm x
25.4mm)
Interface Component
2.7” dia. X 0.9”
(68.6mm dia. x 22.9mm)
Sensor Component
8.5” (215.9mm)
Interconnecting Cable
Weight
12 oz. (340g)
Mounting
SAE J1810 5-hole bolt
pattern
Can mount to 1.25” BSP or 1.5” NPT using
available adapters
Environmental
Parameter
Value
IEC 60945 Classification
Exposed
Degree of Protection
IP67
Operating Temperature
-25°C to 55°C
Storage Temperature
-40°C to 70°C
Relative Humidity
93%RH @40° per IEC60945-8.2
Vibration
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s
2
per IEC 60945-8.7
Rain and Spray
12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8
Solar Radiation
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
Corrosion (Salt Mist)
4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Electromagnetic Emission
Conducted and Radiated Emission per IEC 60945-9
Electromagnetic Immunity
Conducted, Radiated, Supply, and ESD per IEC 60945-10
Safety Precautions
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12